Pass NFPA CFPS PDF Dumps Recently Updated 190 Questions [Q35-Q55]

Share

Pass NFPA CFPS PDF Dumps | Recently Updated 190 Questions

Updated Test Engine to Practice CFPS Dumps & Practice Exam


NFPA CFPS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Information and Analysis for Fire Protection and Fire Science: In this section, Fire protection consultants will be evaluated on their ability to conduct fire loss investigations, fire analysis, and protection calculations. Their ability to assess fire dynamics and the impacts on building occupants is crucial for ensuring proper safety measures are in place.
Topic 2
  • Organizing for Fire and Rescue Services: This section will evaluate the skills of Fire protection consultants in pre-incident planning, incident command, and emergency service operations. They will be assessed on their ability to develop and implement an effective Incident Command System (ICS) and ensure fire and emergency services comply with regulations.
Topic 3
  • Detection and Alarm: In this topic, Fire protection consultants will need to demonstrate their expertise in the operational characteristics of fire alarm systems and detection technologies. They will be tested on their ability to apply relevant codes, inspect systems, and ensure compliance with safety standards.
Topic 4
  • Confining Fires: Fire protection consultants will be tested on their ability to recommend and ensure the proper installation and maintenance of fire-resistant construction, including firewalls and barriers. This section will assess their knowledge of smoke control methods and their ability to assist in the design of systems that limit fire spread, ensuring that buildings are equipped to confine fires and protect occupants.
Topic 5
  • Fire Suppression: This topic covers the knowledge of fire suppression systems, including routine maintenance, testing, and system design considerations. Fire protection consultants will be expected to demonstrate their ability to evaluate fire suppression systems, such as sprinklers and non-water-based systems, and ensure their proper functionality following codes and local policies.

 

NEW QUESTION # 35
Which factor plays a significant role in most industrial fire and explosion losses?

  • A. Mechanical
  • B. Process
  • C. External
  • D. Human

Answer: D

Explanation:
The answer is C. Human factor plays a significant role in most industrial fire and explosion losses. According to a study by Allianz Global Corporate & Specialty (AGCS), human error is the cause of 80% of all industrial accidents, including fires and explosions1. Human error can include mistakes, negligence, violations, or sabotage. Some examples of human errors that can lead to fires and explosions are:
Improper handling or storage of flammable or combustible materials
Failure to follow safety procedures or regulations
Lack of training or supervision
Poor maintenance or inspection of equipment or machinery
Ignoring or disabling alarms or warning systems
Smoking or using open flames near hazardous areas
Intentional or accidental ignition of explosives or incendiaries
To prevent or reduce the impact of human errors, industrial facilities should implement effective risk management strategies, such as:
Providing regular and adequate training and education for workers and managers Establishing and enforcing clear and consistent safety policies and rules Conducting thorough and frequent audits and inspections Installing and maintaining reliable fire protection systems and equipment Developing and practicing emergency response and evacuation plans Encouraging a positive safety culture and communication among all stakeholders


NEW QUESTION # 36
What does not require any external power to function and instead relies on specific construction methods and the installation of materials products and building elements to meet well-defined fire performance requirements?

  • A. Prescription code
  • B. Performance-based code
  • C. Building codes
  • D. Passive fire protection

Answer: D


NEW QUESTION # 37
What is the maximum allowable sound pressure level (SPL) for a fire alarm system?

  • A. 50 dBA
  • B. 30 dBA
  • C. 100 dBA
  • D. 130 dBA

Answer: C

Explanation:
According to NFPA 72, the maximum sound pressure level (SPL) for a fire alarm system is 110 dBA at the minimum hearing distance from the audible appliance 1. However, this limit can be exceeded if the sound pressure level measured 2 000 mm above floor level is not more than 100 dBA 2. Sound pressure level is a measure of the intensity of sound at a given point in space, expressed in decibels (dB). The higher the SPL, the louder the sound. For comparison, a normal conversation is about 60 dB, a jet engine is about 140 dB, and a gunshot is about 160 dB 3. Reference: Sound Pressure Levels - NFPA; NFPA fire alarm sound level - EntirelySafe.com; Subsection 907.5 - Occupant notification systems - Casetext; How Loud Is a Fire Alarm In Decibels (dB)? With Noise Comparison Chart; The Ontario Building Code | Audibility of Alarm Systems.


NEW QUESTION # 38
The types of overspray collectors associated with spray booths can be categorized into venturi scrubbers, waterfall scrubbers, dry filter, and

  • A. baffle maze.
  • B. cyclone separator.
  • C. vertical oscillator.
  • D. cartridge filter.

Answer: D

Explanation:
The types of overspray collectors associated with spray booths can be categorized into venturi scrubbers, waterfall scrubbers, dry filter, and cartridge filter. Venturi scrubbers use a high-velocity water spray to capture the overspray particles in a turbulent zone. Waterfall scrubbers use a curtain of water flowing over a perforated plate to wash down the overspray. Dry filter collectors use a series of filters, such as paper, fiberglass, or synthetic media, to trap the overspray. Cartridge filter collectors use pleated cartridges with high surface area and efficiency to capture the overspray. These collectors also have a self-cleaning mechanism that uses compressed air to dislodge the overspray from the cartridges.


NEW QUESTION # 39
Which of the following is the highest level of Personal Protective Equipment (PPE) for hazardous materials response?

  • A. Level C
  • B. Level D
  • C. Level B
  • D. Level A

Answer: D


NEW QUESTION # 40
In Type II, (111) construction, columns supporting more than one floor are required to have a fire resistance rating of:

  • A. 3 hours
  • B. 1 hour
  • C. 3/4 hour
  • D. 0 hour

Answer: B


NEW QUESTION # 41
Central heating appliances are divided into four broad categories; central furnaces, floor furnaces, and:

  • A. Salamanders
  • B. Radiator
  • C. Boilers
  • D. Stoves

Answer: C


NEW QUESTION # 42
Where is the bacterium that causes plague commonly found?

  • A. On rodents
  • B. In rotting wood
  • C. In decomposing animals
  • D. In animal stool

Answer: B


NEW QUESTION # 43
The typical discharge coefficient of a solid stream nozzle for a standard orifice with sharp edges is?

  • A. 0.8
  • B. 0.95
  • C. 0.75
  • D. 0.62

Answer: D

Explanation:
Explanation
0.62
The discharge coefficient of a solid stream nozzle for a standard orifice with sharp edges is a dimensionless number that indicates the ratio of the actual flow rate to the theoretical flow rate of the nozzle. The discharge coefficient depends on the geometry and the flow conditions of the nozzle. According to the web search results, the typical discharge coefficient of a solid stream nozzle for a standard orifice with sharp edges is about 0.62, which means that the actual flow rate is about 62% of the theoretical flow rate.This value is based on the experiments conducted by the National Bureau of Standards (now NIST) and reported in the paper
"Discharge Coefficients of Fire Nozzles"1.The paper also provides a formula to calculate the discharge coefficient for different nozzle diameters and pressures123


NEW QUESTION # 44
How often must a smoke detector connected to a fire alarm panel be visually inspected?

  • A. Annually
  • B. Semiannually
  • C. Monthly
  • D. Quarterly

Answer: C


NEW QUESTION # 45
A value system designed to have a duration of four (4) hours would allow a maximum fire flow of______.

  • A. 4, 500 gpm (17.033 L/min)
  • B. 3, 500 gpm (13.248 L/min)
  • C. 5, 500 spm (20.818 L/min)
  • D. 2.500gpm(9,463L/min)

Answer: B


NEW QUESTION # 46
What is me minimum number of cycles used for joint system movement testing of a Class ll firestopping system?

  • A. 100 cycles
  • B. 10 cycles
  • C. 500 cycles
  • D. 30 cycles

Answer: A


NEW QUESTION # 47
The removal of flammable vapors by displacement for cleaning a storage tank can be accomplished by displacement with air, inert gas and

  • A. sodium bicarbonate
  • B. earth
  • C. water
  • D. absorbant

Answer: C

Explanation:
Explanation
The removal of flammable vapors by displacement for cleaning a storage tank can be accomplished by displacement with air, inert gas, and water. Water is a common method of displacing flammable vapors from tanks, as it is readily available, inexpensive, and non-reactive with most fuels. Water can be sprayed into the tank to create a water seal that prevents the vapors from escaping and reduces the oxygen concentration in the tank. Water can also be used to rinse the tank walls and remove any residual fuel. However, water displacement may not be suitable for some tanks that contain water-sensitive or water-soluble fuels, or for tanks that have limited drainage or disposal facilities.
References:ust permanent closure requirements - Nevada;A Guide to Safety in Confined Spaces - CDC Stacks;Fire Explosion Prevention - Visual Encyclopedia of Chemical Engineering ...


NEW QUESTION # 48
A building provides sleeping facility, with no cooking facility for individual or occupants is what type of occupancy?

  • A. Apartment
  • B. Hotel
  • C. Dormitory
  • D. Lodging and rooming

Answer: C

Explanation:
Hotel:
Any building or group of buildings that provide sleeping rooms for transients.


NEW QUESTION # 49
in a single-story general industrial occupancy protected by an NFPA 13 system, what is the allowed travel distance?

  • A. 250(1 (78 m)
  • B. 1500(106 m
  • C. 3000(91 m
  • D. 400 ft (122 m)

Answer: A


NEW QUESTION # 50
Wildfires can have far-reaching impacts on the natural environment. Which tool can help land managers to create plans for landscape repair to minimize post-fire impacts on water supplies and other sensitive ecosystems?

  • A. Satellite imagery
  • B. Early detection cameras
  • C. Deployable heat detectors
  • D. Electronic data collection

Answer: A


NEW QUESTION # 51
The incident command system (ICS) under the National Incident Management System (NIMS) has how many major functional areas?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
The ICS under the NIMS has five major functional areas: command, operations, planning, logistics, and finance/administration12. These functional areas are also known as sections and are headed by section chiefs. The command section is responsible for the overall management and direction of the incident. The operations section is responsible for the tactical actions to achieve the incident objectives. The planning section is responsible for the collection, evaluation, and dissemination of information and the development of the incident action plan. The logistics section is responsible for providing the resources and services needed to support the incident. The finance/administration section is responsible for the financial, administrative, and legal aspects of the incident12. Reference:
Fire Protection Handbook, NFPA 2008, Chapter 6.3.1, "Incident Command System".
NIMS Components - Guidance and Tools, FEMA, "Incident Command System".


NEW QUESTION # 52
To be effective, liquid nerve agents must be in ________ form.

  • A. liquid
  • B. aerosol
  • C. solid
  • D. dried

Answer: D


NEW QUESTION # 53
What type of load is the weight of items such as furnishings, people, and equipment?

  • A. Live
  • B. Residual
  • C. Dead
  • D. Static

Answer: C

Explanation:
Explanation
The weight of items such as furnishings, people, and equipment is called dead load. Dead load is the permanent load that is applied to a structure or a component of a structure1. It includes the weight of the structure itself, as well as any fixed attachments or equipment2. Dead load is one of the factors that determines the fire resistance rating of a structure or a component3. References:
NFPA 557: Standard for Determination of Fire Loads for Use in Structural Fire Protection Design An Overview of Fire Protection for Structural Engineers SFPE Handbook of Fire Protection Engineering, 5th edition


NEW QUESTION # 54
What oven class utilizes a special processing atmosphere to prevent the oxidation of the metal during the heating process?

  • A. Class B
  • B. Class A
  • C. Cass D
  • D. Class C

Answer: B

Explanation:
Class A ovens and furnaces are heat utilization equipment operating at approximately atmospheric pressure wherein there is a potential explosion or fire hazard that could be occasioned by the presence of flammable volatiles or combustible materials processed or heated in the furnace. Such flammable volatiles or combustible materials can, for instance, originate from any one of the following:
(a) Paints, powders, inks, and adhesives from finishing processes, such as dipped, coated, sprayed, and impregnated Materials (b) Substrate material.
(c) Wood, paper, and plastic pallets, spacers, or packaging materials
(d) Polymerization or other molecular rearrangements Potentially flammable materials, such as quench oil, water-borne finishes, cooling oil, or cooking oils, that present a hazard are ventilated according to Class A standards.
Class B ovens and furnaces are heat utilization equipment operating at approximately atmospheric pressure wherein there are no flammable volatiles or combustible materials being heated.
Class C ovens and furnaces are those in which there is a potential hazard due to a flammable or other special atmosphere being used for treatment of material in process. This type of furnace can use any type of heating system and includes a special atmosphere supply system(s). Also included in the Class C classification are integral quench furnaces and molten salt bath furnaces.
Class D furnaces are vacuum furnaces that operate at temperatures that exceed ambient to over
5000 XF (2760 XC) and at
pressures from vacuum to several atmospheres during heating using any type of heating system. These furnaces can include the use of special processing atmospheres. During gas quenching, these furnaces may operate at pressures from below atmospheric to over a gauge pressure of 100 psi (690 kPag).


NEW QUESTION # 55
......

NFPA CFPS Dumps Cover Real Exam Questions: https://www.examcollectionpass.com/NFPA/CFPS-practice-exam-dumps.html

Dumps Collection CFPS Test Engine Dumps Training With 190 Questions: https://drive.google.com/open?id=1F7b4nNEZ_KOEoFo9JB12JqbXSileJXKx