Get Real DES-4122 Exam Dumps [Sep-2023] Practice Tests [Q37-Q58]

Share

Get Real DES-4122 Exam Dumps [Sep-2023] Practice Tests

Last DES-4122 practice test reviews: Practice Test EMC dumps

NEW QUESTION # 37
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. FPGA
  • B. OCP
  • C. NDC
  • D. PCIe

Answer: A


NEW QUESTION # 38
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

  • A. Ensures that the installed operating system is authentic
  • B. Ensures that the server has a valid Service Tag number
  • C. Ensures that the server boots only when connected to a verified network
  • D. Ensures that no unauthorized BIOS or firmware codes are run

Answer: D


NEW QUESTION # 39
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

  • A. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
  • B. The license cannot be upgraded because the user will not allow the server to be powered on
  • C. The license cannot be upgraded on a single PSU system
  • D. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server

Answer: C


NEW QUESTION # 40
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

  • A. System Profile
  • B. HyperThreading
  • C. Number of Cores per Processor
  • D. Virtualization Technology

Answer: C


NEW QUESTION # 41
Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?

  • A. 6x2 5" drives
  • B. 8x2 5" drives
  • C. 2x3.5" drives
  • D. 4x 3.5" drives

Answer: C


NEW QUESTION # 42
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Write Intensive
  • B. Read Intensive
  • C. Quad-level cell
  • D. Single-level cell

Answer: D


NEW QUESTION # 43
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?

  • A. Hot-plug power supply, 750 W - qty 1
  • B. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2
  • C. Hot-plug power supply, 1100W - qty 1
  • D. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2

Answer: A


NEW QUESTION # 44
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?

  • A. Enable the Match Firmware of Replaced Part setting in the system BIOS
  • B. Install and configure a repository manager
  • C. Configure servers to access the remote firmware repository
  • D. Enable the Collect System Inventory On Restart (CSIOR) attribute

Answer: A


NEW QUESTION # 45
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

  • A. Access the iDRAC and view the last boot cycle video capture entry
  • B. Export the Server profile and analyze for any POST errors
  • C. Reload the BIOS firmware
  • D. Access the Lifecycle Controller and view the last boot cycle video capture entry

Answer: A


NEW QUESTION # 46
What is the correct order of steps taken during the BIOS/UEFI Recovery process?

Answer:

Explanation:


NEW QUESTION # 47
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Write Intensive
  • B. Single-level cell
  • C. Read Intensive
  • D. Quad-level cell

Answer: C


NEW QUESTION # 48
What is a key feature introduced in OpenManage Mobile v2.0?

  • A. Access servers remotely through OME
  • B. Access a Virtual Console (VNC over SSH) securely
  • C. Access SupportAssist reports
  • D. Access iDRAC remotely

Answer: C


NEW QUESTION # 49
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?

  • A. OpenManage Server Administrator
  • B. iDRAC Web GUI
  • C. SupportAssist Enterprise
  • D. Virtual Console; press F2 after rebooting system

Answer: B


NEW QUESTION # 50
A technician working with a Dell EMC PowerEdge 14G server observes the PCIe indicator turn solid amber What should they do to take corrective action upon checking the System Event log?

  • A.
  • B.
  • C.
  • D.

Answer: D


NEW QUESTION # 51
After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.
Which setting should be changed?

  • A. System Profile to Performance in the iDRAC GUI
  • B. Rebuild Rate in the BIOS settings
  • C. Rebuild Rate in the iDRAC GUI
  • D. System Profile to Performance in the BIOS settings

Answer: C


NEW QUESTION # 52
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?

  • A. Reuse an existing vFlash SD card from a 14G server
  • B. Use a configuration option to convert BOSS to a virtual vFlash
  • C. Use a configuration option to convert an NVMe drive to a virtual vFlash
  • D. Reuse an existing vFlash SD card from either a 13G or 14G server

Answer: A


NEW QUESTION # 53
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?

  • A. Firmware: Upgrade to latest available version
    Configuration Apply always
  • B. Firmware Disabled
    Configuration Apply only if firmware match
  • C. Firmware: Match firmware of replaced part
    Configuration Apply always
  • D. Firmware Allow version upgrade only
    Configuration: Disabled

Answer: C


NEW QUESTION # 54
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
A)

B)

C)

D)

  • A. Option C
  • B. Option A
  • C. Option D
  • D. Option B

Answer: A


NEW QUESTION # 55
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?

  • A. Both the iDRAC and the LCC can be rolled back
  • B. The iDRAC cannot be rolled back and the LCC cannot be rolled back
  • C. The LCC can be rolled back; the iDRAC cannot be rolled back
  • D. The iDRAC can be rolled back; the LCC cannot be rolled back

Answer: C


NEW QUESTION # 56
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option C
  • B. Option A
  • C. Option D
  • D. Option B

Answer: A


NEW QUESTION # 57
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?

  • A. 512 GB
  • B. 128 GB
  • C. 64 GB
  • D. 256 GB

Answer: B


NEW QUESTION # 58
......

Get Ready to Pass the DES-4122 exam with EMC Latest Practice Exam : https://www.examcollectionpass.com/EMC/DES-4122-practice-exam-dumps.html